Files
opensbi/platform/kendryte/k210/platform.c
Samuel Holland 99b01ab610 platform: Drop timer warm init and exit hooks
Now that driver lifecycle is managed from within the SBI timer core,
platforms need only to initialize the driver once during cold init.
Remove the remaining platform hooks that are no longer used.

Signed-off-by: Samuel Holland <samuel.holland@sifive.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
2024-11-05 17:39:31 +05:30

190 lines
4.1 KiB
C

/*
* SPDX-License-Identifier: BSD-2-Clause
*
* Copyright (c) 2019 Western Digital Corporation or its affiliates.
*
* Authors:
* Damien Le Moal <damien.lemoal@wdc.com>
*/
#include <sbi/riscv_asm.h>
#include <sbi/riscv_encoding.h>
#include <sbi/sbi_const.h>
#include <sbi/sbi_platform.h>
#include <sbi/sbi_system.h>
#include <sbi_utils/fdt/fdt_helper.h>
#include <sbi_utils/fdt/fdt_fixup.h>
#include <sbi_utils/ipi/aclint_mswi.h>
#include <sbi_utils/irqchip/plic.h>
#include <sbi_utils/serial/sifive-uart.h>
#include <sbi_utils/timer/aclint_mtimer.h>
#include "platform.h"
extern const char dt_k210_start[];
unsigned long fw_platform_init(unsigned long arg0, unsigned long arg1,
unsigned long arg2, unsigned long arg3,
unsigned long arg4)
{
return (unsigned long)&dt_k210_start[0];
}
static struct plic_data plic = {
.addr = K210_PLIC_BASE_ADDR,
.size = K210_PLIC_BASE_SIZE,
.num_src = K210_PLIC_NUM_SOURCES,
};
static struct aclint_mswi_data mswi = {
.addr = K210_ACLINT_MSWI_ADDR,
.size = ACLINT_MSWI_SIZE,
.first_hartid = 0,
.hart_count = K210_HART_COUNT,
};
static struct aclint_mtimer_data mtimer = {
.mtime_freq = K210_ACLINT_MTIMER_FREQ,
.mtime_addr = K210_ACLINT_MTIMER_ADDR +
ACLINT_DEFAULT_MTIME_OFFSET,
.mtime_size = ACLINT_DEFAULT_MTIME_SIZE,
.mtimecmp_addr = K210_ACLINT_MTIMER_ADDR +
ACLINT_DEFAULT_MTIMECMP_OFFSET,
.mtimecmp_size = ACLINT_DEFAULT_MTIMECMP_SIZE,
.first_hartid = 0,
.hart_count = K210_HART_COUNT,
.has_64bit_mmio = true,
};
static u32 k210_get_clk_freq(void)
{
u32 clksel0, pll0;
u64 pll0_freq, clkr0, clkf0, clkod0, div;
/*
* If the clock selector is not set, use the base frequency.
* Otherwise, use PLL0 frequency with a frequency divisor.
*/
clksel0 = k210_read_sysreg(K210_CLKSEL0);
if (!(clksel0 & 0x1))
return K210_CLK0_FREQ;
/*
* Get PLL0 frequency:
* freq = base frequency * clkf0 / (clkr0 * clkod0)
*/
pll0 = k210_read_sysreg(K210_PLL0);
clkr0 = 1 + (pll0 & 0x0000000f);
clkf0 = 1 + ((pll0 & 0x000003f0) >> 4);
clkod0 = 1 + ((pll0 & 0x00003c00) >> 10);
pll0_freq = clkf0 * K210_CLK0_FREQ / (clkr0 * clkod0);
/* Get the frequency divisor from the clock selector */
div = 2ULL << ((clksel0 & 0x00000006) >> 1);
return pll0_freq / div;
}
static int k210_system_reset_check(u32 type, u32 reason)
{
return 1;
}
static void k210_system_reset(u32 type, u32 reason)
{
u32 val;
val = k210_read_sysreg(K210_RESET);
val |= K210_RESET_MASK;
k210_write_sysreg(val, K210_RESET);
while (1);
}
static struct sbi_system_reset_device k210_reset = {
.name = "kendryte_k210_reset",
.system_reset_check = k210_system_reset_check,
.system_reset = k210_system_reset
};
static int k210_early_init(bool cold_boot)
{
if (!cold_boot)
return 0;
sbi_system_reset_add_device(&k210_reset);
return sifive_uart_init(K210_UART_BASE_ADDR, k210_get_clk_freq(),
K210_UART_BAUDRATE);
}
static int k210_final_init(bool cold_boot)
{
void *fdt;
if (!cold_boot)
return 0;
fdt = fdt_get_address_rw();
fdt_cpu_fixup(fdt);
fdt_fixups(fdt);
return 0;
}
static int k210_irqchip_init(bool cold_boot)
{
int rc;
u32 hartid = current_hartid();
if (cold_boot) {
rc = plic_cold_irqchip_init(&plic);
if (rc)
return rc;
}
return plic_warm_irqchip_init(&plic, hartid * 2, hartid * 2 + 1);
}
static int k210_ipi_init(bool cold_boot)
{
int rc;
if (cold_boot) {
rc = aclint_mswi_cold_init(&mswi);
if (rc)
return rc;
}
return aclint_mswi_warm_init();
}
static int k210_timer_init(void)
{
return aclint_mtimer_cold_init(&mtimer, NULL);
}
const struct sbi_platform_operations platform_ops = {
.early_init = k210_early_init,
.final_init = k210_final_init,
.irqchip_init = k210_irqchip_init,
.ipi_init = k210_ipi_init,
.timer_init = k210_timer_init,
};
const struct sbi_platform platform = {
.opensbi_version = OPENSBI_VERSION,
.platform_version = SBI_PLATFORM_VERSION(0x0, 0x01),
.name = "Kendryte K210",
.features = 0,
.hart_count = K210_HART_COUNT,
.hart_stack_size = SBI_PLATFORM_DEFAULT_HART_STACK_SIZE,
.heap_size =
SBI_PLATFORM_DEFAULT_HEAP_SIZE(K210_HART_COUNT),
.platform_ops_addr = (unsigned long)&platform_ops
};