* SPDX-License-Identifier: BSD-2-Clause
*
* Copyright (c) 2022 Andes Technology Corporation
*
* Authors:
* Yu Chien Peter Lin <peterlin@andestech.com>
*/
#include <sbi_utils/fdt/fdt_helper.h>
#include <sbi_utils/timer/fdt_timer.h>
#include <sbi_utils/timer/andes_plmt.h>
extern struct plmt_data plmt;
static int fdt_plmt_cold_timer_init(const void *fdt, int nodeoff,
const struct fdt_match *match)
{
int rc;
unsigned long plmt_base;
rc = fdt_parse_plmt_node(fdt, nodeoff, &plmt_base, &plmt.size,
&plmt.hart_count);
if (rc)
return rc;
plmt.time_val = (u64 *)plmt_base;
plmt.time_cmp = (u64 *)(plmt_base + 0x8);
rc = fdt_parse_timebase_frequency(fdt, &plmt.timer_freq);
if (rc)
return rc;
rc = plmt_cold_timer_init(&plmt);
if (rc)
return rc;
return 0;
}
static const struct fdt_match timer_plmt_match[] = {
{ .compatible = "andestech,plmt0" },
{},
};
struct fdt_timer fdt_timer_plmt = {
.match_table = timer_plmt_match,
.cold_init = fdt_plmt_cold_timer_init,
};