Commit Graph

6 Commits

Author SHA1 Message Date
Icenowy Zheng
a8ee82cd8c lib: utils/ipi: mswi: add T-Head C9xx CLINT compatible
Althoug the MTIMER part of a C9xx CLINT differs from a SiFive one, the
MSWI part is compliant.

Add T-Head C9xx CLINT compatible string to fdt_ipi_mswi code, sharing
the same codepath with SiFive CLINT.

Signed-off-by: Icenowy Zheng <uwu@icenowy.me>
Reviewed-by: Anup Patel <anup@brainfault.org>
2022-12-17 11:01:00 +05:30
Samuel Holland
6f1fe98c2f lib: utils/timer: Remove Allwinner D1 CLINT compatibles
The allwinner,sun20i-d1-clint compatible string is not documented in any
official binding, so it should not be used by drivers.

The MSWI in the D1 CLINT is compatible with the ACLINT specification, so
it can take advantage of generic driver support. However, that is only
possible if the MSWI and MTIMER are split into separate DT nodes. This
means the final binding for this device is likely to be incompatible
with what is implemented here.

Remove this compatible string from the driver to prevent it from
appearing in a stable version and causing future issues.

Signed-off-by: Samuel Holland <samuel@sholland.org>
Reviewed-by: Anup Patel <anup@brainfault.org>
2022-06-22 10:55:37 +05:30
Samuel Holland
7738345396 lib: utils/timer: Add a separate compatible for the D1 CLINT
The CLINT in the Allwinner D1 SoC apparently does not support 64-bit
MMIO access. A property was added to support this quirk (and that
property was copied to the ACLINT MTIMER code). However, since this
difference in behavior makes the D1 CLINT incompatible with the SiFive
CLINT's programming interface, a better solution is to use a separate
compatible string.

Signed-off-by: Samuel Holland <samuel@sholland.org>
Reviewed-by: Anup Patel <anup@brainfault.org>
2022-06-21 09:20:59 +05:30
Samuel Holland
fab0379bb6 lib: utils/fdt: Require match data to be const
Match data stores hardware attributes which do not change at runtime, so
it does not need to be mutable. Make it const.

Reviewed-by: Guo Ren <guoren@kernel.org>
Reviewed-by: Xiang W <wxjstz@126.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
Signed-off-by: Samuel Holland <samuel@sholland.org>
2022-05-30 10:32:35 +05:30
Anup Patel
f3a0eb8583 lib: utils/fdt: Extend fdt_parse_aclint_node() function
The fdt_parse_aclint_node() is used to parse DT node for SiFive
CLINT, ACLINT MTIMER, and ACLINT MSWI devices.

The ACLINT MTIMER has undergone following changes:
1) MTIMER DT node now requires separate addresses in for MTIME
   register and MTIMECMPx registers in the reg DT property.
2) MTIMER DT node might have no interrupts-extended DT property
   when the MTIMER device has no associated HARTs (i.e. the
   MTIMER device has no MTIMECMPx registers)

This patch extends fdt_parse_aclint_node() to handle above
mentioned changes in ACLINT MTIMER DT bindings.

Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Atish Patra <atish.patra@wdc.com>
2021-08-14 09:02:39 +05:30
Anup Patel
56fc5f7618 lib: utils/ipi: Add FDT based ACLINT MSWI IPI driver
We add a new FDT based ACLINT MSWI IPI driver which works for both
CLINT device and standalone ACLINT MSWI device.

Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Bin Meng <bmeng.cn@gmail.com>
Reviewed-by: Xiang W <wxjstz@126.com>
2021-06-24 09:39:51 +05:30