forked from Mirrors/opensbi
		
	include: sbi_platform: Introduce HART index to HART id table
A platform can have discontinuous and/or sparse HART ids so we cannot always assume a set of HARTs with continuous HART ids. This patch adds support for discontinuous and sparse HART ids by introducing HART index to HART id table. This table has platform hart_count entries and it maps HART index to HART id. The HART index to HART id table has only two restrictions: 1. HART index < sbi_platform hart_count 2. HART id < SBI_HARTMASK_MAX_BITS Example1: Let's say we have a platform with 2 HART ids 11 and 22, for such a a platform: hart_count = 2 hart_index2id[0] = 11 hart_index2id[1] = 22 Example2: Let's say we have a platform with 5 HARTs ids 0, 1, 2, 3, and 4 but out of these HART with id 0 is not usable so for such a platform: hart_count = 5 hart_index2id[0] = -1U hart_index2id[1] = 1 hart_index2id[2] = 2 hart_index2id[3] = 3 hart_index2id[4] = 4 OR hart_count = 4 hart_index2id[0] = 1 hart_index2id[1] = 2 hart_index2id[2] = 3 hart_index2id[3] = 4 With HART index to HART id table in place, the hart_disabled() callback is now redundant so we remove it as well. Signed-off-by: Anup Patel <anup.patel@wdc.com> Reviewed-by: Bin Meng <bmeng.cn@gmail.com> Reviewed-by: Atish Patra <atish.patra@wdc.com>
This commit is contained in:
		@@ -165,10 +165,12 @@ static int fu540_timer_init(bool cold_boot)
 | 
			
		||||
	return clint_warm_timer_init();
 | 
			
		||||
}
 | 
			
		||||
 | 
			
		||||
static bool fu540_hart_disabled(u32 hartid)
 | 
			
		||||
{
 | 
			
		||||
	return (FU540_HARITD_DISABLED & (1UL << hartid)) ? TRUE : FALSE;
 | 
			
		||||
}
 | 
			
		||||
static u32 fu540_hart_index2id[FU540_HART_COUNT - 1] = {
 | 
			
		||||
	[0] = 1,
 | 
			
		||||
	[1] = 2,
 | 
			
		||||
	[2] = 3,
 | 
			
		||||
	[3] = 4,
 | 
			
		||||
};
 | 
			
		||||
 | 
			
		||||
static int fu540_system_down(u32 type)
 | 
			
		||||
{
 | 
			
		||||
@@ -192,7 +194,6 @@ const struct sbi_platform_operations platform_ops = {
 | 
			
		||||
	.timer_event_stop	= clint_timer_event_stop,
 | 
			
		||||
	.timer_event_start	= clint_timer_event_start,
 | 
			
		||||
	.timer_init		= fu540_timer_init,
 | 
			
		||||
	.hart_disabled		= fu540_hart_disabled,
 | 
			
		||||
	.system_reboot		= fu540_system_down,
 | 
			
		||||
	.system_shutdown	= fu540_system_down
 | 
			
		||||
};
 | 
			
		||||
@@ -202,7 +203,8 @@ const struct sbi_platform platform = {
 | 
			
		||||
	.platform_version	= SBI_PLATFORM_VERSION(0x0, 0x01),
 | 
			
		||||
	.name			= "SiFive Freedom U540",
 | 
			
		||||
	.features		= SBI_PLATFORM_DEFAULT_FEATURES,
 | 
			
		||||
	.hart_count		= FU540_HART_COUNT,
 | 
			
		||||
	.hart_count		= (FU540_HART_COUNT - 1),
 | 
			
		||||
	.hart_index2id		= fu540_hart_index2id,
 | 
			
		||||
	.hart_stack_size	= SBI_PLATFORM_DEFAULT_HART_STACK_SIZE,
 | 
			
		||||
	.platform_ops_addr	= (unsigned long)&platform_ops
 | 
			
		||||
};
 | 
			
		||||
 
 | 
			
		||||
		Reference in New Issue
	