mirror of
https://github.com/riscv-software-src/opensbi.git
synced 2025-08-24 23:41:23 +01:00

Instead of having console_putc() and console_getc() callbacks in platform operations, it will be much simpler for console driver to directly register these operations as device to the sbi_console implementation. Signed-off-by: Anup Patel <anup.patel@wdc.com> Reviewed-by: Alistair Francis <alistair.francis@wdc.com> Reviewed-by: Xiang W <wxjstz@126.com>
205 lines
4.3 KiB
C
205 lines
4.3 KiB
C
/*
|
|
* SPDX-License-Identifier: BSD-2-Clause
|
|
*
|
|
* Copyright (c) 2019 Western Digital Corporation or its affiliates.
|
|
*/
|
|
|
|
#include <sbi/riscv_asm.h>
|
|
#include <sbi/riscv_encoding.h>
|
|
#include <sbi/sbi_const.h>
|
|
#include <sbi/sbi_platform.h>
|
|
|
|
/*
|
|
* Include these files as needed.
|
|
* See config.mk PLATFORM_xxx configuration parameters.
|
|
*/
|
|
#include <sbi_utils/irqchip/plic.h>
|
|
#include <sbi_utils/serial/uart8250.h>
|
|
#include <sbi_utils/sys/clint.h>
|
|
|
|
#define PLATFORM_PLIC_ADDR 0xc000000
|
|
#define PLATFORM_PLIC_NUM_SOURCES 128
|
|
#define PLATFORM_HART_COUNT 4
|
|
#define PLATFORM_CLINT_ADDR 0x2000000
|
|
#define PLATFORM_UART_ADDR 0x09000000
|
|
#define PLATFORM_UART_INPUT_FREQ 10000000
|
|
#define PLATFORM_UART_BAUDRATE 115200
|
|
|
|
static struct plic_data plic = {
|
|
.addr = PLATFORM_PLIC_ADDR,
|
|
.num_src = PLATFORM_PLIC_NUM_SOURCES,
|
|
};
|
|
|
|
static struct clint_data clint = {
|
|
.addr = PLATFORM_CLINT_ADDR,
|
|
.first_hartid = 0,
|
|
.hart_count = PLATFORM_HART_COUNT,
|
|
.has_64bit_mmio = TRUE,
|
|
};
|
|
|
|
/*
|
|
* Platform early initialization.
|
|
*/
|
|
static int platform_early_init(bool cold_boot)
|
|
{
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* Platform final initialization.
|
|
*/
|
|
static int platform_final_init(bool cold_boot)
|
|
{
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* Initialize the platform console.
|
|
*/
|
|
static int platform_console_init(void)
|
|
{
|
|
/* Example if the generic UART8250 driver is used */
|
|
return uart8250_init(PLATFORM_UART_ADDR, PLATFORM_UART_INPUT_FREQ,
|
|
PLATFORM_UART_BAUDRATE, 0, 1);
|
|
}
|
|
|
|
/*
|
|
* Initialize the platform interrupt controller for current HART.
|
|
*/
|
|
static int platform_irqchip_init(bool cold_boot)
|
|
{
|
|
u32 hartid = current_hartid();
|
|
int ret;
|
|
|
|
/* Example if the generic PLIC driver is used */
|
|
if (cold_boot) {
|
|
ret = plic_cold_irqchip_init(&plic);
|
|
if (ret)
|
|
return ret;
|
|
}
|
|
|
|
return plic_warm_irqchip_init(&plic, 2 * hartid, 2 * hartid + 1);
|
|
}
|
|
|
|
/*
|
|
* Initialize IPI for current HART.
|
|
*/
|
|
static int platform_ipi_init(bool cold_boot)
|
|
{
|
|
int ret;
|
|
|
|
/* Example if the generic CLINT driver is used */
|
|
if (cold_boot) {
|
|
ret = clint_cold_ipi_init(&clint);
|
|
if (ret)
|
|
return ret;
|
|
}
|
|
|
|
return clint_warm_ipi_init();
|
|
}
|
|
|
|
/*
|
|
* Send IPI to a target HART
|
|
*/
|
|
static void platform_ipi_send(u32 target_hart)
|
|
{
|
|
/* Example if the generic CLINT driver is used */
|
|
clint_ipi_send(target_hart);
|
|
}
|
|
|
|
/*
|
|
* Clear IPI for a target HART.
|
|
*/
|
|
static void platform_ipi_clear(u32 target_hart)
|
|
{
|
|
/* Example if the generic CLINT driver is used */
|
|
clint_ipi_clear(target_hart);
|
|
}
|
|
|
|
/*
|
|
* Initialize platform timer for current HART.
|
|
*/
|
|
static int platform_timer_init(bool cold_boot)
|
|
{
|
|
int ret;
|
|
|
|
/* Example if the generic CLINT driver is used */
|
|
if (cold_boot) {
|
|
ret = clint_cold_timer_init(&clint, NULL);
|
|
if (ret)
|
|
return ret;
|
|
}
|
|
|
|
return clint_warm_timer_init();
|
|
}
|
|
|
|
/*
|
|
* Get platform timer value.
|
|
*/
|
|
static u64 platform_timer_value(void)
|
|
{
|
|
/* Example if the generic CLINT driver is used */
|
|
return clint_timer_value();
|
|
}
|
|
|
|
/*
|
|
* Start platform timer event for current HART.
|
|
*/
|
|
static void platform_timer_event_start(u64 next_event)
|
|
{
|
|
/* Example if the generic CLINT driver is used */
|
|
clint_timer_event_start(next_event);
|
|
}
|
|
|
|
/*
|
|
* Stop platform timer event for current HART.
|
|
*/
|
|
static void platform_timer_event_stop(void)
|
|
{
|
|
/* Example if the generic CLINT driver is used */
|
|
clint_timer_event_stop();
|
|
}
|
|
|
|
/*
|
|
* Check reset type and reason supported by the platform.
|
|
*/
|
|
static int platform_system_reset_check(u32 type, u32 reason)
|
|
{
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* Reset the platform.
|
|
*/
|
|
static void platform_system_reset(u32 type, u32 reason)
|
|
{
|
|
}
|
|
|
|
/*
|
|
* Platform descriptor.
|
|
*/
|
|
const struct sbi_platform_operations platform_ops = {
|
|
.early_init = platform_early_init,
|
|
.final_init = platform_final_init,
|
|
.console_init = platform_console_init,
|
|
.irqchip_init = platform_irqchip_init,
|
|
.ipi_send = platform_ipi_send,
|
|
.ipi_clear = platform_ipi_clear,
|
|
.ipi_init = platform_ipi_init,
|
|
.timer_value = platform_timer_value,
|
|
.timer_event_stop = platform_timer_event_stop,
|
|
.timer_event_start = platform_timer_event_start,
|
|
.timer_init = platform_timer_init,
|
|
.system_reset_check = platform_system_reset_check,
|
|
.system_reset = platform_system_reset
|
|
};
|
|
const struct sbi_platform platform = {
|
|
.opensbi_version = OPENSBI_VERSION,
|
|
.platform_version = SBI_PLATFORM_VERSION(0x0, 0x00),
|
|
.name = "platform-name",
|
|
.features = SBI_PLATFORM_DEFAULT_FEATURES,
|
|
.hart_count = 1,
|
|
.hart_stack_size = SBI_PLATFORM_DEFAULT_HART_STACK_SIZE,
|
|
.platform_ops_addr = (unsigned long)&platform_ops
|
|
};
|