Now that driver lifecycle is managed from within the SBI irqchip core,
platforms need only to initialize the driver once during cold init.
Remove the remaining platform hooks that are no longer used.
Signed-off-by: Samuel Holland <samuel.holland@sifive.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
Currently, each platform keeps track of which irqchip driver is in use
and calls its warm init function. Since the generic platform may use
multiple irqchip drivers, it has logic to track an array of drivers.
The code is simplified and made common across platforms by treating warm
init and exit as properties of the driver, not the platform. Then the
platform's only role is to select and prepare a driver during cold boot.
For now, only add a .warm_init hook, since none of the existing drivers
need an .exit hook. It could be added in the future if needed.
Signed-off-by: Samuel Holland <samuel.holland@sifive.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
The per-hart PLIC pointer is not really specific to FDT platforms. Move
it into the main driver and drop the extra wrapper functions.
Signed-off-by: Samuel Holland <samuel.holland@sifive.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
Move the PLIC save/restore functions inside the driver, so they can be
reused on any platform that needs them. The memory needed to store the
PLIC context is also allocated by the driver. The PM data cannot be
completely encapsulated, as some platforms (including Allwinner D1) need
to program the IRQ enable status to a sideband interrupt controller for
wakeup capability.
Signed-off-by: Samuel Holland <samuel.holland@sifive.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
This removes platform-specific arguments to plic_warm_irqchip_init(),
which makes the driver independent from the platform after cold init,
and allows for further refactoring.
Signed-off-by: Samuel Holland <samuel.holland@sifive.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
This needs to be in the base PLIC driver as part of the power management
save/restore flow.
This is also in preparation for moving the PLIC information in the
scratch area to the base PLIC driver. After that change, the FDT PLIC
layer will be unable to look up the `struct plic_data` after cold boot.
Signed-off-by: Samuel Holland <samuel.holland@sifive.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
Instead of using a global array indexed by hartid, we should use
scratch space to save per-HART PLIC pointer and PLIC context numbers.
Signed-off-by: Anup Patel <apatel@ventanamicro.com>
Reviewed-by: Andrew Jones <ajones@ventanamicro.com>
Let's use heap allocation in PLIC, APLIC, and IMSIC irqchip drivers
instead of using a fixed size global array.
Signed-off-by: Anup Patel <apatel@ventanamicro.com>
Reviewed-by: Andrew Jones <ajones@ventanamicro.com>
Currently the context save/restore helpers writes/reads the provided
array using an index whose maximum value is determined by PLIC, which
potentially may disagree with the caller to these helpers.
Add a parameter to ask the caller to provide the size limit of the
array to ensure no out-of-bound access happens.
Signed-off-by: Bin Meng <bmeng@tinylab.org>
Reviewed-by: Anup Patel <anup@brainfault.org>
Currently the priority save/restore helpers writes/reads the provided
array using an index whose maximum value is determined by PLIC, which
potentially may disagree with the caller to these helpers.
Add a parameter to ask the caller to provide the size limit of the
array to ensure no out-of-bound access happens.
Signed-off-by: Bin Meng <bmeng@tinylab.org>
Reviewed-by: Anup Patel <anup@brainfault.org>
Add compatible string for Andestech NCEPLIC100 found on Renesas RZ/Five SoC
which is equipped with AX45MP AndesCore.
While at it drop the comma after the sentinel as it does not make sense to
have a comma after a sentinel, as any new elements must be added before the
sentinel.
dts example (Single-core AX45MP):
soc: soc {
....
plic: interrupt-controller@12c00000 {
compatible = "renesas,r9a07g043-plic", "andestech,nceplic100";
#interrupt-cells = <2>;
#address-cells = <0>;
riscv,ndev = <511>;
interrupt-controller;
reg = <0x0 0x12c00000 0 0x400000>;
clocks = <&cpg CPG_MOD R9A07G043_NCEPLIC_ACLK>;
power-domains = <&cpg>;
resets = <&cpg R9A07G043_NCEPLIC_ARESETN>;
interrupts-extended = <&cpu0_intc 11 &cpu0_intc 9>;
};
....
};
Signed-off-by: Lad Prabhakar <prabhakar.mahadev-lad.rj@bp.renesas.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
Reviewed-by: Bin Meng <bmeng@tinylab.org>
The delegation bit is lost along with the rest of the PLIC state when
the CPU power domain in the Allwinner D1 is powered down, so the PLIC
needs to be re-delegated to S-mode during the hart resume path.
Reviewed-by: Anup Patel <anup@brainfault.org>
Signed-off-by: Samuel Holland <samuel@sholland.org>
These functions save/restore the state of the PLIC associated with the
current hart. The context save/restore functions only manipulate a
single context, since most likely the M-mode context is unused and does
not need to be saved.
Signed-off-by: Samuel Holland <samuel@sholland.org>
Reviewed-by: Anup Patel <anup@brainfault.org>
Using "void *" in arithmetic causes errors with strict compiler settings:
"error: pointer of type 'void *' used in arithmetic [-Werror=pointer-arith]"
Avoid these by calculating on "char *" where 1-byte data size is assumed.
Signed-off-by: Jukka Laitinen <jukkax@ssrc.tii.ae>
Reviewed-by: Dong Du <Dd_nirvana@sjtu.edu.cn>
Reviewed-by: Xiang W <wxjstz@126.com>
Reviewed-by: Anup Patel <anup@brainfault.org>
The T-HEAD PLIC implementation requires setting a delegation bit
to allow access from S-mode. Now that the T-HEAD PLIC has its own
compatible string, set this bit automatically from the PLIC driver,
instead of reaching into the PLIC's MMIO space from another driver.
Signed-off-by: Samuel Holland <samuel@sholland.org>
Reviewed-by: Bin Meng <bmeng.cn@gmail.com>
Reviewed-by: Anup Patel <anup.patel@wdc.com>
We can have multiple matching DT nodes of the same FDT irqchip
driver so in this case we should call cold_init() for all matching
DT nodes instead of just first matching DT node.
Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Atish Patra <atish.patra@wdc.com>
We extend all PLIC functions to have a "struct plic_data *"
parameter pointing to PLIC details. This allows platforms to
use these functions for multiple PLIC instances.
Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Atish Patra <atish.patra@wdc.com>
The "target_hart" and "hart_count" parameters of PLIC cold and
warm init functions are only used for sanity checks and not
required in PLIC initialization.
Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Atish Patra <atish.patra@wdc.com>
We add simple irqchip framework which will select and use irqchip driver
based on details in FDT passed by previous booting stage.
Signed-off-by: Anup Patel <anup.patel@wdc.com>
Reviewed-by: Atish Patra <atish.patra@wdc.com>